 AC-DC Chassis Mount 600-1000 Watts CPK Series
*
THE XPERTS IN POWER
Up to 2 kW Peak Rating * Wide Output Voltage Adjustment * Up to 500 W Convection Cooled * Optional Conformal Coating * Optional Remote ON/OFF * Optional AC, DC & Fan Fail Signals
Specification
Input
Input Voltage * Input Frequency * Inrush Current * Power Factor * Earth Leakage Current * 85-264 VAC (120-350 VDC) 47-63 Hz 20/40 A typical at 115/230 VAC 0.98 typical at 230 VAC at 100% load 0.75 mA max at 230 VAC 60Hz for 0.50 mA add suffix `-E', for 0.15 mA add suffix `-G' Switching Frequency Vertical Terminal block Din Rail Mounting Fan Fitted N+1 Operation Alarms (Optional) Conformal Coating * * * * * * * 85 kHz 15% active PFC 130 kHz 15% forward converter Add suffix `-T' to model numbers Add suffix `-NI' to model numbers Add suffix `-F' to model number (only available on 24 V units) Option `-W' & external oring diodes For AC fail, DC fail and fan fail add suffix `-W' to model number Add suffix `-L' to model numbers
Output
Output Voltage Output Voltage Adjustment Minimum Load Start Up time Hold Up time Initial Set Accuracy Drift Line Regulation Load Regulation Ripple & Noise Overvoltage Protection Overcurrent Protection Remote ON/OFF (Optional) * * * * * * * * * * * * * See Table See Table No minimum load required 500 ms max at 100 VAC 100% load 20 ms typical at 100 VAC 100% load 1% max 0.4% 0.4% from low line to high line 0.7% max from 0-100% load 0.8% max pk-pk 20 MHz bandwidth 115-140% of Vnom, recycle input to restart 101% of peak current auto recovery Add suffix `-R' to model number ON 4.5-12.5 V (open circuit) between RC+ and RCOFF 0 to 0.5 V (short circuit) between RC+ and RC-
Environmental
Operating Temperature * -10 C to +70 C (fan cooled) Derate linearly above +50 C to 60% load at +70 C. For convection cooled rating - See Derating Curves -20 C to +75 C 20-90% RH non-condensing 20 G, 11 ms once each, X, Y & Z axis 2 G, 3 min period, 60 min each along X, Y & Z axis
Storage Temperature Relative Humidity Shock Vibration
* * * *
EMC & Safety
Emissions * EN55022 level B conducted (level A with option E not available with option G) EN55022 level B radiated EN61000-4-2 Level 2 contact Level 3 air EN61000-4-3 Level 3 EN61000-4-4 Level 4 EN61000-4-5 Level 3 line to line Level 4 line to ground UL60950, C-UL (CSA60950), EN60950, EN50178
General
Efficiency Isolation * * 86-89% dependent on model 3000 VAC Input to Output 2000 VAC Input to Ground
ESD Susceptibility Radiated Susceptibility EFT/Burst Surge Safety Approvals
* * * * *
*
*
www.xpplc.com
sales@xpplc.com
OUTPUT VOLTAGE & CURRENT RATINGS
Output Voltage V (21.6-27.0 V (27.0-33.0 V (33.0-41.0 V (41.0-52.8 V (21.6-27.0 V (27.0-33.0 V (33.0-41.0 V (41.0-52.8 V (21.6-27.0 V (27.0-33.0 V (33.0-41.0 V (41.0-52.8 Output Current (85-130 VAC IN) Max Fan(1) Peak2) 14.0 A 21.0 A 25.0 A 11.0 A 16.5 A 20.0 A 9.0 A 14.0 A 16.5 A 6.5 A 10.5 A 12.5 A 17.0 A 25.0 A 42.0 A 13.5 A 20.0 A 33.5 A 11.0 A 16.5 A 28.0 A 8.0 A 12.5 A 21.0 A 21.0 A 33.0 A 63.0 A 16.5 A 26.0 A 50.0 A 14.0 A 22.0 A 42.0 A 10.5 A 16.5 A 31.5 A Output Current (180-264 VAC IN) Max Fan(1) Peak(2) 15.0 A 25.0 A 31.0 A 12.0 A 20.0 A 24.5 A 10.0 A 16.5 A 20.5 A 7.0 A 12.5 A 15.5 A 19.0 A 31.5 A 63.0 A 15.0 A 24.5 A 50.0 A 12.5 A 20.5 A 42.0 A 9.0 A 15.5 A 31.5 A 25.0 A 42.0 A 83.0 A 20.0 A 33.5 A 66.0 A 16.5 A 28.0 A 55.0 A 11.5 A 21.0 A 41.5 A Efficiency 86% 87% 87% 89% 88% 88% 89% 89% 88% 88% 89% 89%
(3)
CPK
Model Number CPK600PS24 CPK600PS30 CPK600PS36 CPK600PS48 CPK750PS24 CPK750PS30 CPK750PS36 CPK750PS48 CPK1KPS24 CPK1KPS30 CPK1KPS36 CPK1KPS48
24.0 30.0 36.0 48.0 24.0 30.0 36.0 48.0 24.0 30.0 36.0 48.0
V) V) V) V) V) V) V) V) V) V) V) V)
Notes 1. Add suffix `-F' to model number to receive unit with fan fitted (24 V units only) alternatively 60 CFM system airflow must be provided. 2. Peak rating is valid for each model number and is not dependent on whether the max rating is convection or fan cooled. 3. Efficiency is specified at 230 VAC and 100% load.
*
Mechanical Details 600 Watts
NOTE: `-F' option (24 V models only) increases the overall height from 65 to 96 mm. Weight 1.5 kg
For pin out tables see 1000 W mechanical details.
Mechanical Details 750 Watts
NOTE: `-F' option (24 V models only) increases the overall height from 70 to 101 mm. Weight 1.9 kg
For pin out tables see 1000 W mechanical details.
www.xpplc.com
sales@xpplc.com
Mechanical Details 1000 Watts
NOTE: `-F' option (24 V models only) increases the overall height from 75 to 106 mm. Weight 2.5 kg
SYMBOL VB CB +V +V -V -V FG N L
PIN CONNECTIONS FUNCTION Voltage Balance Current Balance Output Terminal (+) Output Terminal (+) Output Terminal (-) Output Terminal (-) Frame Ground AC (N) AC(L)
SCREW M3
M4
PIN 1 2 3-8 9 10 11-12 13 14
OPTIONAL CN3 PIN CONNECTIONS FUNCTION SYMBOL ROF + (-R) RC+ ROF - (-R) RCN/C NC LV Alarm (-W) LV+ LV Alarm Ground (-W) LVN/C NC PF Alarm + (-W) PF+ PF Alarm Ground (-W) PF-
Connector CN3 S148B-PHDSS
Mating Connector PHDR-14VS
Terminal Mfr Chain: SPHD-002T-P.0.5 Loose: BPHD-001T-P0.5 J.S.T BPHD-002T-P0.5
For mating loom kit for optional CN3 order part number "CPK CN3 LOOM"
Average 21 A max per pin for TB1
Forced Air Cooling (60 CFM)
The temperature points A and B shown are marked on the psu chassis. * Point A must be 60C and point B must be 65C at Ta = 50C. * Point A must be 80C and point B must be 80C at Ta = 70C. The confirmation of the temperatures of point A and B is not necessary if option fan "-F" is used. Load factor is dependent on input voltage and is an average power figure. (See part number table).
Convection Cooled - Derating Curves
Convection Cooled CPK 750
Installation Method Note: 1. Output ripple & noise may be outside specification. 2. Load factor dependent on input voltage (see part number table) and is an average power figure.
CPK 600
CPK 1000
www.xpplc.com
sales@xpplc.com
Peak Loading
3 conditions must be satisfied: 1. t1 10 (second) (Ppxt1) +(Poxt2) 2. Pave = rated power t1+t2 t1 3. Duty = 0.35 (refer to graphs) t1+t2
CPK 600
CPK 750
CPK1000
1. CPK115V convection 2. CPK115V forced air
3. CPK230V convection 4. CPK230V forced air
Remote ON/OFF
Option `-R'
Voltage Applied Between RC (+) and RC (-) SW ON (4.5 - 12.5 V open circuit) SW OFF (0-0.5 V short circuit) Output ON OFF Example of using Remote ON/OFF If external power source is in the range of 4.5-12.5 V, current limit resistor R is not required. If external power source exceeds 12.5 V, current limit resistor R must be connected. To calculate the current limit resistance use following equation: R () = Vcc - (1.1+Ri x 0.005) 0.005 Where; Vcc = External Power Source Ri = The internal resistance (780) Remote ON/OFF circuit (RC (+), RC (-) ) is isolated from input, output and FG.
Alarms
Option "-W" * -W is available for detecting low input alarm (PF), detecting low output voltage (LV) and operating N+1 redundancy. * Alarm specifications are shown in Table. * Each alarm (PF, LV) is isolated from input, output and FG.
PF Alarm If line voltage falls below 85 VAC or fan stops Output of alarm Open collector method Good: Low (0-08. V, 1 mA max) Fail: 50 V max Open collector method Good: Low (0-08. V, 1 mA max) Fail: 50 V max
If the output voltage falls out of specified Notice: 1. When the output is over current (intermittent current), the alarm is unsettled status. 2. When parallel operating without connecting diode, LV alarm is not operating.
LV
Internal circuit of PF
Internal circuit of LV
www.xpplc.com
sales@xpplc.com
Rev 3.0


▲Up To Search▲   

 
Price & Availability of CPK1KPS24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X